ZHANG Siyuan1,2,SUN Simin1,2,GUO Shuai1,WANG Xiaofang1,2,ZHU Zhiping1,2
(1.Institute of Engineering Thermophysics, Chinese Academy of Sciences, Beijing 100190, China;2. School of Engineering Science, University of Chinese Academy of Sciences, Beijing 100049, China)
Abstract: In order to separate semi coke and gas ,this paper has designed a single factor variable test on performance of horizontal cyclone separator with single discharge pipe. The effects of key structural parameters (diameter of discharge pipe D4, angle between exhaust pipe and discharge pipe β, length of guide body L4) on performance indexes (separation efficiency η, air leakage rate δ, pressure drop ΔP1 between inlet and discharge pipe of separator, pressure drop ΔP2 between inlet and exhaust pipe of separator) were investigated. The results show that when D4 increases from 60 mm to 80 mm, η changes from 94.9% to 95.6%. δ and ΔP1 increase gradually with D4. When β is 55°, η reaches the maximum. As β increases, δ changes little. ΔP1 and ΔP2 reach the maximum when β is 50°. When L4 is 300 mm, η、 ΔP1 and ΔP2 reach the minimum. δ changes with L4 by 2% under load condition.
Keywords: horizontal cyclone; pressure loss; separation efficiency; air leak rate
中图分类号:TB47
文献标志码:A
文章编号:1008-5548(2021)06-0112-09
DOI:10.13732/j.issn.1008-5548.2021.06.014
收稿日期: 2021-03-25,修回日期:2021-09-13,在线出版时间:2021-10-18 17:13。
基金项目:中国科学院科技成果转移转化重点专项项目,编号:Y929030401。
第一作者简介:张思源(1997—),男,硕士研究生,研究方向为循环流化床煤气化。E-mail: zhangsiyuan@iet.cn。
通信作者简介:王小芳(1982—),女,博士,高级工程师,硕士生导师,研究方向为煤气化。E-mail: wangxiaofang@iet.cn。