Abstract: In order to study the failure or fault of cyclone separator caused by abnormal change of process parameters in fluid catalytic cracking unit (FCCU),and the large amount of catalyst run-off caused by them,the process parameters affecting separation operation of cyclone separator and catalyst run-off were summarized,and the parameters affecting process fault were analyzed,such as inlet velocity,inlet concentration,rapid fluctuation of system pressure,coking blockage of dipleg,poor discharge of feed leg outlet,and physical properties of catalyst. By checking the parameters of the cyclone separator,the fault reason and location of the cyclone separator can be effectively diagnosed.

Keywords:fluid catalytic cracking unit; cyclone; fault diagnosis