Separation performance contrastive study of micro hydrocyclone for ultrafine particles

LIU Peikun, NIU Zhiyong, YANG Xinghua, ZHANG Yuekan

(College of Mechanical and Electrical Engineering, Shandong University of Science and Technology, Qingdao 266590, China)

Abstract:The small diameter hydrocyclone has not a good separation effect. Therefore,a kind of 8 mm in diameter micro hydrocyclone was designed and its separation performance was compared with that of 10 mm in diameter hydrocyclone. The numerical simulated and experimental results show that,compared with the 10 mm hydrocyclone, the underflow output of8 mm hydrocyclone increases by 3.8%, the overflow concentration reduces by 5.3%, the underflow concentration is unchanged, the comprehensive classification efficiency of-2 μm particles increases by 6%, the comprehensive classification efficiency of-5 μm particles increases by 3.1%,the cut size reduces about 0.7 μm.

Keywords: micro hydrocyclone; separation performance; comprehensive classification efficiency; cut size

中图分类号:TD98        文献标志码:A

文章编号:1008-5548(2016)06-0001-06

DOI:10.13732/j.issn.1008-5548.2016.06.001

收稿日期:2016-03-08,修回日期:2016-10-19,在线出版时间:2016-12-06。

基金项目:国家自然科学基金项目,编号 :21276145;山东省科技发展计划项目,编号:2014GGB019G3。

第一作者简介:刘培坤(1971—),男,博士,教授,硕士生导师,研究方向为固液分离技术与装备。E-mail:lpk710128@163.com。