XIA Defeng, LIN Guangrong, WANG Mingxian, CAI Jin
(School of Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013, China)
Abstract:To find out the factors influencing the cyclone pressure loss and separation efficiency, the design and manufacture of filters were optimized. With the aid of computational fluid dynamics Fluent software, using the orthogonal simulation method, the effect of different trachea insertion depths, cone cylinder diameters and entrance widths on the separation efficiency and total pressure drop of the standard Stairmand type cyclone was analyzed. The results show that when the trachea insertion depth is 80 mm, the bottom diameter of cone is 100 mm, the entrance is 30 mm, and the minimum total pressure drop can be achieved. When the trachea insertion depth is 120 mm, the bottom diameter of the cone is 50 mm,the entrance width is 30 mm, and the dust separation efficiency is the highest.
Keywords: cyclone; separation efficiency; pressure drop; Fluent software; orthogonal simulation
中图分类号:TD454 文献标志码:A
文章编号:1008-5548(2015)01-0100-03
DOI:10.13732/j.issn.1008-5548.2015.01.022
收稿日期:2014-04-24, 修回日期:2014-05-17,在线出版时间:2015-03-02。
第一作者简介:夏得峰(1986—),男,硕士研究生,研究方向为旋风除尘器的优化。 电话:18361810979,E-mail:568732911@qq.com。