ISSN 1008-5548

CN 37-1316/TU

Journal Online  2015 Vol.21
<Go BackNo.3

Improved Method for Determining Protection Zone of Atmospheric Environment for Ash Storage Field

WANG Han, LIU Hui, LI Lizhen, WANG Lei

(China Institute for Radiation Protection, Taiyuan 030006, China)

Abstract: In view of the large deviation of dust amount calculated by existing calculation formulas for ash storage field, using the backstepping method of dust source strength from actual measured total suspended particles concentration in the periphery of an ash storage field of a certain power station, the calculation formulas of dust source strength for the ash storage field were compared and evaluated. A more accurate calculating formula of dust amount for the ash storage field was recommended. An improved method for determining the protection zone of atmospheric environment for the ash storage field was presented. The results show that the recommended formula and determined protection zone of atmospheric environment have high accuracy and conservation.

Keywords: ash storage field; dust amount of backstepping; protection zone of atmospheric environment; method for determining

中图分类号:X323         文献标志码:A

文章编号:1008-5548(2015)03-0089-04

DOI:10.13732/j.issn.1008-5548.2015.03.021

收稿日期:2014-09-08, 修回日期:2014-10-10,在线出版时间:2015-06-24。

第一作者简介:王寒(1958—),男,硕士,研究员,研究方向为环境影响评价和环境科学。 电话:13934206155,E-mail:772644554@qq.com。